Multifunction Measuring Instrument
DS 300 for Compressed Air and Gases
SPECIAL FEATURES
• Internal data memory
• Inner diameter adjustable in hand-held
instrument
• Easy installation and removal of the
sensor under pressure via 1/2” ball valve
• 4 hours power independent
measurements
TECHNICAL DATA
MOBILE CONSUMPTION PROBE VA 300:
Measured variables: m/s, m
³
/h bzw. m
³
/min, l/min
Inner diameter freely adjustable in CS 2390-5
Data memory: 6.000 measured values
Principle of meas.: calorimetric measurement
Measuring medium: Air, gas
Measuring range: 0 ... 26.400 m
³
/h
(see table below)
Accuracy without
measuring section: ± 4% m.v., ± 3% m.v. with
5 point ISO precision certificate
Application temp.: -30 up to 110°C probe tube
-30 up to 80 °C housing
Operating pressure: up to 50 bar
Probe tube: stainless steel, 1.4301
total length standard
220 mm, Ø 9 mm
Screw thread: G1/2”
Power supply: hand-held instrum. 12 VDC
STATIONARY CONSUMPTION PROBE VA 300-80:
Additionally to the above mentioned data:
Variables freely selectable in DS 300:
m
³
/s, m
³
/h, m³/min, l/min l/sec, ft/min, cfm
Diameter freely adjustable in DS 300
Accuracy with measuring section:
± 3% m.v., ± 2% m.v. with 5 point ISO precision
certificate
Power supply: 12-30 VDC
FLOW MEAS. RANGES MOBILE + STATIONARY
Standard Max
Inch mm VA 300-80 VA 300-120 Unit
VA 300-81 VA 300-121
1/4 6,0 0.8 ... 85 1.0 ... 120 l/min
1/2” 16,1 2.5 ... 750 3.5 ... 1,100 l/min
3/4 21,7 0.3 ... 90 0.4 ... 120 m
³
/h
1 27,3 0.5 ... 150 0.6 ... 200 m
³
/h
1 1/4 36,0 0.9 ... 280 1.2 ... 350 m
³
/h
1 1/2” 41,8 1.2 ... 370 1.5 ... 500 m
³
/h
2” 53,1 2 ... 600 2.5 ... 800 m
³
/h
2 1/2” 68,9 3.5 ... 1,100 5 ... 1,500 m
³
/h
3” 84,9 5 ... 1,600 7 ... 2,200 m
³
/h
4 110,3 9 ... 2,700 12 ... 3,600 m
³
/h
5” 133,7 13 ... 4,000 18 ... 5,300 m
³
/h
6” 162,3 18 ... 5,800 25 ... 8,000 m
³
/h
8” 200 26 ... 8,800 33 ... 11,700 m
³
/h
10” 250 40 ... 13,700 52 ... 18,900 m
³
/h
12” 300 60 ... 19,800 80 ... 26,400 m
³
/h
according to DIN 1945, ISO1217 related to 20°C,
1000 mbar
DESCRIPTION ORDER NO.
Mobile set for consumption
measurement (max. version)
consisting of: 0600 1010
CS 2390-5 mobile hand-held instr. 0560 2395
3 measuring channels
Rechargeable battery pack for long- 0515 1002
term measuring approx. 4 hours
Mains adapter 12 V DC 230 V AC 2390 2290
Portable consumption probe 3300 0121
VA 300-121 for CS 2390-5, max.
version with 2 m cable to CS 2390-5,
including certificate
CS Soft Software for display in graphic 3200 1101
or table form
PC connection cable V24 RS 232 2390 1909
USB RS 232 adapter 3200 1013
Professional transport case 0554 6000
Further accessories, not included in the set:
5 point precision calibration with 3200 0001
ISO certificate
Mobile pressure dew point probe 0699 3003
(-80 to +50 °Ctd) incl. meas. chamber,
2 m cable to CS 2390-5
Please take order details and further accessories
from the price list